CAN Network CANnet: Difference between revisions
Jump to navigation
Jump to search
RSbySCHÄFER (talk | contribs) No edit summary |
RSbySCHÄFER (talk | contribs) No edit summary |
||
Line 4: | Line 4: | ||
To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages. | To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages. | ||
[[Image:ASK5000.jpg|thumb|Power Cable 5m]] | [[Image:ASK5000.jpg|thumb|Power Cable 10m / 5m]] | ||
[[Image: | [[Image:SSK2000.jpg|thumb|Interface Cable 50cm]] | ||
[[Image:KVK4000.jpg|thumb|Node Connecting Cable 4m / 50cm / 20cm]] | [[Image:KVK4000.jpg|thumb|Node Connecting Cable 4m / 50cm / 20cm]] | ||
[[Image:KK100.jpg|thumb| | [[Image:KK100.jpg|thumb|Bypass Coupling 10cm]] | ||
[[Image:NT120.jpg|thumb|Network Terminal]] | [[Image:NT120.jpg|thumb|Network Terminal]] | ||
Line 17: | Line 17: | ||
Following cable segments are available | Following cable segments are available | ||
*Power Cable ASK10000 | |||
*Power Cable ASK5000 | *Power Cable ASK5000 | ||
* | *Interface Cable SSK500 | ||
*Node Connecting Cable KVK4000 | *Node Connecting Cable KVK4000 | ||
*Node Connecting Cable KVK500 | *Node Connecting Cable KVK500 | ||
*Node Connecting Cable KVK200 | *Node Connecting Cable KVK200 | ||
*Cable | *Bypass Cable UEB100 | ||
*Network Terminal NT120 <br /> | *Network Terminal NT120 <br /> | ||
<br /> | <br /> |
Revision as of 09:51, 20 October 2008
The cable system consists of 4 wires with a nominal size of 0,75 mm². Two wires (bl/rd) are used for power supply and two wires (wt/bl)are used as bus line. The wires of power supply and the wires of BUS line are always twisted together.
To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages.
- No customisation of cable segments
- No spring clips
- No connecting diagram neccassary
- Wrong terminal connections impossibly
Following cable segments are available
- Power Cable ASK10000
- Power Cable ASK5000
- Interface Cable SSK500
- Node Connecting Cable KVK4000
- Node Connecting Cable KVK500
- Node Connecting Cable KVK200
- Bypass Cable UEB100
- Network Terminal NT120
Example for Connection: CANnet Topology