The CANsmall CS08 is used for the connection of landing fixtures for lifts. It is available for face plate mounting or quick fastening.
The CANsmall CS08 is used for the connection of landing fixtures for lifts. It is available for face plate mounting or quick fastening.


Small dimensions approx. 55 x 35 mm.
No DIP switches or jumper necessary.
Node number and Baudrate are adjustable.
Auto baud detection is possible.


Geringe Abmessung ca. 55 x 35 mm.
Switching elements with recall light are connectable in 3- or 4-wire technology, common cathode.  
Keine DIP-Schalter oder Jumper erforderlich.
Knotennummer und Baudrate ist konfigurierbar.
Autobauderkennung möglich.
 
Schaltelemente mit Quittierung sind in 3-Draht oder 4-Draht Technik gem. Kathode anschließbar.
Das Einlesen des Eingangs bei gesetztem Ausgang ist bei beiden Anschlussvarianten möglich.
Das Einlesen des Eingangs bei gesetztem Ausgang ist bei beiden Anschlussvarianten möglich.



Revision as of 11:15, 8 February 2008

Ruftableauknoten CANsmall CS08


Manufacturer

SCHAEFER GmbH

Profil

CiA-417 (hier fehlt noch der Link zum Molex Stecker)


Description

The CANsmall CS08 has 8 I/O terminals, 8 output terminals and contains the following virtual devices: Input Panel Unit and Output Panel Unit. The I/O terminals can be used for the calls, inputs- and outputs. So any input signal can be read in and sent to the CAN Bus as input-function. Also the output signals of the different lift controllers are read out via the I/O terminals or respectively output terminals.

The CANsmall CS08 is used for the connection of landing fixtures for lifts. It is available for face plate mounting or quick fastening.

Small dimensions approx. 55 x 35 mm. No DIP switches or jumper necessary. Node number and Baudrate are adjustable. Auto baud detection is possible.

Switching elements with recall light are connectable in 3- or 4-wire technology, common cathode. Das Einlesen des Eingangs bei gesetztem Ausgang ist bei beiden Anschlussvarianten möglich.


Following version are available:


  • CANsmall CS08_xST (4 slots up to 2 I/O-clamps per slot)
    • CANsmall CS08_VST (Vertical clamps)
    • CANsmall CS08_HST (Horizontal clamps)


  • CANsmall CS08_xPM (1 slot f. SCHAEFER Diplay)
    • CANsmall CS08_VPM (Vertical clamps)
    • CANsmall CS08_HPM (Horizontal clamps)


Topology

Die Ruftableaus sind komplett vorverdrahtet von der Fa. SCHAEFER GmbH zu beziehen. Eine Verdrahtung von Komponenten außerhalb des Ruftableaus ist nicht vorgesehen. Die komplette Schacht-Verdrahtung beschränkt sich ausschließlich auf die Busleitung und Stromversorgung. Die Reihenfolge der Ruftableaus ist unter logischen Gesichtspunkten unerheblich. Hierdurch sind potentielle Fehlerquellen bei der Schachtverdrahtung nahezu ausgeschlossen.

State

Following version are deliverable:

  • CS08_VST
  • CS08_VPM
  • CS08_HST
  • CS08_HPM


Picture CANsmall CS08_VST

Picture CANsmall CS08_VPM

Picture CANsmall CS08_HST

Picture CANsmall CS08_HPM