Node-IDs

From CANopen-Lift
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

The node-IDs depents on the topology of the CANopen network. Here you can see a recommedation of node-IDs in CANopen-lift networks.

Topology: 2 seperate busses for car and shaft

Node-ID Recommedation:
Node-ID
(dez)
CAN1
local bus
CAN2
shaft/group bus
1 lift controller (Call/car drive/door controller, NMT “flying” master) lift controller G1 (Call/car drive/door controller lift 1, NMT “flying” master)
2 drive (frequency inverter, car drive unit) lift controller G2 (Call/car drive/door controller lift 2, NMT “flying” master)
3 reserved lift controller G3 (Call/car drive/door controller lift 3, NMT “flying” master)
4 encoder/position system 1 (Car position unit 1) lift controller G4 (Call/car drive/door controller lift 4, NMT “flying” master)
5 encoder/position system 2 (Car position unit 2) lift controller G5 (Call/car drive/door controller lift 5, NMT “flying” master)
6 reserved lift controller G6 (Call/car drive/door controller lift 6, NMT “flying” master)
7 door drive unit 1 (door A) lift controller G7 (Call/car drive/door controller lift 7, NMT “flying” master)
8 door drive unit 2 (door B) lift controller G8 (Call/car drive/door controller lift 8, NMT “flying” master)
9 door drive unit 3 (door C) gateway/repeater (Remote data transmission unit 1)
10 gateway (CDG-01) gateway/repeater 2 (Remote data transmission unit 2)
11 reserved (e.g. Wago-I/O) gateway/repeater 3 (Remote data transmission unit 3)
12 reserved (inspection box) gateway/repeater 4 (Remote data transmission unit 4)
13 weight measurement unit gateway/repeater 5 (Remote data transmission unit 5)
14 energy measurent unit gateway/repeater 6 (Remote data transmission unit 6)
15 reserved (emergency call device) gateway/repeater 7 (Remote data transmission unit 7)
16 car call panel node 1 (Car I/O panel 1) gateway/repeater 8 (Remote data transmission unit 8)
17 car call panel node 2 (Car I/O panel 2)  
18 car call panel node 3 (Car I/O panel 3)  
19 car call panel node 4 (Car I/O panel 4)  
20 car call panel node 5 (Car I/O panel 5)  
21 - 84 floor I/O panel 1 to 64
85 - 119 free
120 - 124 reserved
125 default setting of a non-parameterized device and daisy-chain systems
126 firmware update boot loader
127 diagnostic tool