CAN Network CANnet: Difference between revisions
Jump to navigation
Jump to search
RSbySCHÄFER (talk | contribs) No edit summary |
RSbySCHÄFER (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
=Manufacturer= | |||
[[Schaefer GmbH|SCHAEFER GmbH]] | |||
=Profil= | |||
CiA-417 | |||
=Description= | |||
The cable system consists of 4 wires with a nominal size of 0,75 mm². Two wires (bl/rd) are used for power supply and two wires (wt/bl)are used as bus line. The wires of power supply and the wires of BUS line are always twisted together. | The cable system consists of 4 wires with a nominal size of 0,75 mm². Two wires (bl/rd) are used for power supply and two wires (wt/bl)are used as bus line. The wires of power supply and the wires of BUS line are always twisted together. | ||
<br /> | <br /> | ||
To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages. | To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages. | ||
*No customisation of cable segments | *No customisation of cable segments | ||
Line 19: | Line 21: | ||
<br /> | <br /> | ||
Following cable segments are available | =State= | ||
Following cable segments are available<br /> | |||
<br /> | <br /> | ||
=Elements= | |||
[[Image:ASK5000.jpg|thumb|Power Cable 10m / 5m]] | |||
===Power Cable ASK10000=== | |||
===Power Cable ASK5000=== | |||
Description follows! | |||
[[Image:SSK500.jpg|thumb|Interface Cable 50cm]] | |||
===Interface Cable SSK500=== | |||
Description follows! | |||
[[Image:KVK4000.jpg|thumb|Node Connecting Cable 4m / 50cm / 20cm]] | |||
===Node Connecting Cable KVK4000=== | |||
===Node Connecting Cable KVK500=== | |||
===Node Connecting Cable KVK200=== | |||
Description follows! | |||
[[Image:KK100.jpg|thumb|Bypass Coupling 10cm]] | |||
===Bypass Cable UEB100=== | |||
Description follows! | |||
[[Image:NT120.jpg|thumb|Network Terminal]] | |||
===Network Terminal NT120=== | |||
Description follows! | |||
<br /><br /><br /><br /><br /><br /><br /> | |||
=Links= | |||
Example for Connection: [[media:CANnet_Topology.pdf|CANnet Topology]]<br /> | Example for Connection: [[media:CANnet_Topology.pdf|CANnet Topology]]<br /> | ||
Connectors: Under way | Connectors: Under way |
Revision as of 14:58, 21 October 2008
Manufacturer
Profil
CiA-417
Description
The cable system consists of 4 wires with a nominal size of 0,75 mm². Two wires (bl/rd) are used for power supply and two wires (wt/bl)are used as bus line. The wires of power supply and the wires of BUS line are always twisted together.
To realize a simly and reliable installation of a network with CANopen components, the using of preconverted cable segments proffers clearly advantages.
- No customisation of cable segments
- No spring clips
- No connecting diagram neccassary
- Wrong terminal connections impossibly
- Simply expansion of the can network
- No instruments for building a can network neccessary
- No specific knowledge about CANopen neccessary
State
Following cable segments are available
Elements
Power Cable ASK10000
Power Cable ASK5000
Description follows!
Interface Cable SSK500
Description follows!
Node Connecting Cable KVK4000
Node Connecting Cable KVK500
Node Connecting Cable KVK200
Description follows!
Bypass Cable UEB100
Description follows!
Network Terminal NT120
Description follows!
Links
Example for Connection: CANnet Topology
Connectors: Under way