LM-CANopen with display: Difference between revisions

From CANopen-Lift
Jump to navigation Jump to search
(Created page with "thumb|Micelect = Manufacturer = Micelect = Profile = CiA-417 = Interface = *Open Style connector according to DS 303-1 *LEDs indicating the s...")
 
Line 13: Line 13:
= Description =
= Description =
[[File:LM-CAN_xopt.png|thumb|LM-CANopen]]
[[File:LM-CAN_xopt.png|thumb|LM-CANopen]]
<strong>LM-CANopen</strong> is an excellent electronic control unit with CANopen output compatible with all sensors manufactured by MICELECT.
The new universal <strong>LM-CANopen</strong> control with display unit can be used with all sensors manufactured by MICELECT.


The unit uses CANopen communications protocol. Its calibration and configuration are very easy.
This unit uses CANopen® communications protocol and its calibration and configuration is very easy.
8 to 16 inputs models available.
 
We make different versions with CAN propietary protocol too.


<em>MODELS:</em>
<em>MODELS:</em>
* DIN-rail.
* DIN-rail.
* In a IP 65-rated plastic box
* In a IP 65-rated plastic box.
* 8 inputs.
* 16 inputs.
* CAN propietary protocol.


<em>STANDARD FEATURES:</em>
<em>STANDARD FEATURES:</em>
*CANopen® communications
* CANopen® communications according to Cia 417.
*Compatible with all sensors manufactured by MICELECT
* Compatible with all load weighing sensors manufactured by MICELECT.
*Open Style connector according to DS 303-1
* Up to 16 individual sensor measures.
*LEDs indicating the status of the node according to DS 303-3
* High sampling speed.
* Non-connection sensor detection (EMCY codes).
* CAN-bus connection: DS 303-1 (Open Style Connector or 9-pin D-sub connector).
* LEDs indicate the status of the node according to DS 303-3.
* CANopen alarms:
  - Zero-Load.
  - Normal-Load.
  - Full-Load.
  - Overload.
  - Slack rope.
  - Difference of rope.
* LCD and buttons to view and set all CANopen and manufacturer parameters.
* Update firmware button through CANBus connector (with PCAN adapter).


<em>ELECTRICAL FEATURES:</em>
<em>ELECTRICAL FEATURES:</em>
*Power supply voltage 24Vdc
* LEDs indicating the status of the node (DS 303-3).
*Communications CANopen®
* 2.5 kV rms signal and power isolated CAN transceiver.
*Open Style connectors DS 303-1
* isoPower integrated isolated dc-to-dc converter.
*LEDs indicating the status of the node DS 303-3
* Complies with ISO 11898 standard High speed data rates of up to 1 Mbps.
* High common-mode transient immunity: >25 kV/μs.
* DIP switch 120Ω termination resistor.
* Update firmware button through CANBus connector (with PCAN adapter).


<em>MECHANICAL FEATURES:</em>
<em>MECHANICAL FEATURES:</em>
Line 41: Line 62:
<em>OPTIONS</em><br>
<em>OPTIONS</em><br>
<strong>Isolated option</strong>
<strong>Isolated option</strong>
*2.5 kV rms signal and power isolated CAN transceiver
*isoPower® integrated isolated dc-to-dc converter
*Complies with ISO 11898 standard  
*Complies with ISO 11898 standard  
*High speed data rates up to 1 Mbps  
*High speed data rates up to 1 Mbps  
*Slope Control for reduced EMI  
*Slope Control for reduced EMI  
*Thermal shutdown protection  
*Thermal shutdown protection  
*High common-mode transient immunity: >25 kV/μs
*UL recognition
*UL recognition
*2500 V rms for 1 minute per UL 1577
*2500 V rms for 1 minute per UL 1577

Revision as of 14:07, 18 January 2017

Micelect

Manufacturer

Micelect

Profile

CiA-417

Interface

  • Open Style connector according to DS 303-1
  • LEDs indicating the status of the node according to DS 303-3

Description

LM-CANopen

The new universal LM-CANopen control with display unit can be used with all sensors manufactured by MICELECT.

This unit uses CANopen® communications protocol and its calibration and configuration is very easy. 8 to 16 inputs models available.

We make different versions with CAN propietary protocol too.

MODELS:

  • DIN-rail.
  • In a IP 65-rated plastic box.
  • 8 inputs.
  • 16 inputs.
  • CAN propietary protocol.

STANDARD FEATURES:

  • CANopen® communications according to Cia 417.
  • Compatible with all load weighing sensors manufactured by MICELECT.
  • Up to 16 individual sensor measures.
  • High sampling speed.
  • Non-connection sensor detection (EMCY codes).
  • CAN-bus connection: DS 303-1 (Open Style Connector or 9-pin D-sub connector).
  • LEDs indicate the status of the node according to DS 303-3.
  • CANopen alarms:
 - Zero-Load.
 - Normal-Load.
 - Full-Load.
 - Overload.
 - Slack rope.
 - Difference of rope.
  • LCD and buttons to view and set all CANopen and manufacturer parameters.
  • Update firmware button through CANBus connector (with PCAN adapter).

ELECTRICAL FEATURES:

  • LEDs indicating the status of the node (DS 303-3).
  • 2.5 kV rms signal and power isolated CAN transceiver.
  • isoPower integrated isolated dc-to-dc converter.
  • Complies with ISO 11898 standard High speed data rates of up to 1 Mbps.
  • High common-mode transient immunity: >25 kV/μs.
  • DIP switch 120Ω termination resistor.
  • Update firmware button through CANBus connector (with PCAN adapter).

MECHANICAL FEATURES:

  • Weight 1Kg

TEMPERATURE FEATURES:

  • Operating temperature -10ºC / 50ºC

OPTIONS
Isolated option

  • Complies with ISO 11898 standard
  • High speed data rates up to 1 Mbps
  • Slope Control for reduced EMI
  • Thermal shutdown protection
  • UL recognition
  • 2500 V rms for 1 minute per UL 1577

Non isolated option:

  • Fully ISO 11898-2:2003 compliant
  • Loop delay symmetry timing enables reliable communication at data rates up to 2 Mbit/s in the CAN FD fast phase
  • Low ElectroMagnetic Emission (EME) and high ElectroMagnetic Immunity (EMI)
  • Dark green product (halogen free and Restriction of Hazardous Substances (RoHS) compliant)

Status

Available

Picture

Link

micelect.es/LM-CANopen