Lift Hall Call Module LHC-350-20: Difference between revisions
Jump to navigation
Jump to search
Line 12: | Line 12: | ||
*Selective call for UP and DOWN. Ability to connect 2 switching elements with acknowledgment light (Hall Call button). | *Selective call for UP and DOWN. Ability to connect 2 switching elements with acknowledgment light (Hall Call button). | ||
*Selective acknowledgment light for direction indication UP and DOWN. Ability to connect 2 indicator elements. | *Selective acknowledgment light for direction indication UP and DOWN. Ability to connect 2 indicator elements. | ||
*4-Wire-Emulation for 3-Wire- | *4-Wire-Emulation for 3-Wire-Switching elements with acknowledgment light. Allows 3-Wire-Switching elements (combined wire for pushbutton and acknowledgment light) reading back the pushbutton during active acknowledgment light. | ||
*State-LED for Inputs of switching elements and CAN-Bus. | *State-LED for Inputs of switching elements and CAN-Bus. | ||
*Power feed via CAN-Bus-supply. The Module monitors the supply and sets an alarm if it falls under a critical limit. | *Power feed via CAN-Bus-supply. The Module monitors the supply and sets an alarm if it falls under a critical limit. |
Revision as of 11:45, 6 November 2007
Manufacturer
Profile
- CiA-417
Description
Our product Lift Hall Call Module LHC-350-20 offers you:
- Control via CANopen Lift CiA-417.
- Selective call for UP and DOWN. Ability to connect 2 switching elements with acknowledgment light (Hall Call button).
- Selective acknowledgment light for direction indication UP and DOWN. Ability to connect 2 indicator elements.
- 4-Wire-Emulation for 3-Wire-Switching elements with acknowledgment light. Allows 3-Wire-Switching elements (combined wire for pushbutton and acknowledgment light) reading back the pushbutton during active acknowledgment light.
- State-LED for Inputs of switching elements and CAN-Bus.
- Power feed via CAN-Bus-supply. The Module monitors the supply and sets an alarm if it falls under a critical limit.
- The CAN configuration can be saved persistent on the module. No jumper needed for configuration.
- Software updates via CAN-Bus.
State
available