In the CANopen-Standard (CiA-303-1) the allocation of the most common plug connections are standardized. In the application profile for lifts there are recommendation for several plugs for lift components.
Pin-Allocation Plug Mini-Fit Jr. 4 Pins
Pin | Signal | Description |
1 | (CAN_SHLD) | optional shield |
2 | CAN_H | CAN bus signal (dominant high) |
3 | CAN_L | CAN bus signal (dominant low) |
4 | CAN_GND | CAN ground |
5 | (GND) | optional ground power supply (of Pin 6) |
6 | (CAN_V+) | optional external power supply (+24 V) |
Applications
This plug is currently used by the following devices: