LM-CANopen with display

From CANopen-Lift
Jump to navigation Jump to search
Micelect

Manufacturer

Micelect

Profile

CiA-417

Interface

  • Open Style connector according to DS 303-1
  • LEDs indicating the status of the node according to DS 303-3
  • LCD and buttons to view and set all CANopen and manufacturer parameters.

Description

LM-CANopen

The new universal LM-CANopen with display control unit can be used with all load weighin sensors manufactured by MICELECT.

This unit uses CANopen® communications protocol and its calibration and configuration is very easy. 8 to 16 inputs models available.

We make different versions with CAN propietary protocol too.

MODELS:

  • DIN-rail.
  • In a IP 65-rated plastic box.
  • 8 inputs.
  • 16 inputs.
  • CAN propietary protocol.

STANDARD FEATURES:

  • CANopen® communications according to Cia 417.
  • Compatible with all load weighing sensors manufactured by MICELECT.
  • Up to 16 individual sensor measures.
  • High sampling speed.
  • Non-connection sensor detection (EMCY codes).
  • CAN-bus connection: DS 303-1 (Open Style Connector or 9-pin D-sub connector).
  • LEDs indicate the status of the node according to DS 303-3.
  • CANopen alarms:
 - Zero-Load.
 - Normal-Load.
 - Full-Load.
 - Overload.
 - Slack rope.
 - Difference of rope.
  • LCD and buttons to view and set all CANopen and manufacturer parameters.
  • Update firmware button through CANBus connector (with PCAN adapter).

ELECTRICAL FEATURES:

  • LEDs indicating the status of the node (DS 303-3).
  • 2.5 kV rms signal and power isolated CAN transceiver.
  • isoPower integrated isolated dc-to-dc converter.
  • Complies with ISO 11898 standard High speed data rates of up to 1 Mbps.
  • High common-mode transient immunity: >25 kV/μs.
  • DIP switch 120Ω termination resistor.
  • Update firmware button through CANBus connector (with PCAN adapter).

MECHANICAL FEATURES:

  • Weight 1Kg

TEMPERATURE FEATURES:

  • Operating temperature -10ºC / 50ºC

OPTIONS
Isolated option

  • Complies with ISO 11898 standard
  • High speed data rates up to 1 Mbps
  • Slope Control for reduced EMI
  • Thermal shutdown protection
  • UL recognition
  • 2500 V rms for 1 minute per UL 1577

Non isolated option:

  • Fully ISO 11898-2:2003 compliant
  • Loop delay symmetry timing enables reliable communication at data rates up to 2 Mbit/s in the CAN FD fast phase
  • Low ElectroMagnetic Emission (EME) and high ElectroMagnetic Immunity (EMI)
  • Dark green product (halogen free and Restriction of Hazardous Substances (RoHS) compliant)

Status

Available

Picture

Link

micelect.es/LM-CANopen