CAN-Leistungs-Platine CLK-01: Difference between revisions

From CANopen-Lift
Jump to navigation Jump to search
No edit summary
 
Line 8: Line 8:


= Interface =
= Interface =
* Transceiver nach ISO 11898 (Spannungsfestigkeit Busleitungen +/- 30 V)
* transceiver ISO 11898 conform (bus proof voltage +/- 30 V)
* Bitrate und -timing nach CiA DS-301  
* bitrate and -timing CiA DS-301 conform
* galvanisch getrennt
* galvanic insulated
* Autobaud
* auto baud detection
* Stecker:
* connector:
** D-Sub 9-Pin
** D-Sub 9-Pin
** RJ45
** RJ45
** Open Style 3polig  
** Open Style with 3 contacts  
* NodeID 12 (parametrierbar)
* NodeID 12 (parametrizable)
* eine Status-LED nach CiA DR-303-3
* one state LED CiA DR-303-3 conform
* Softwareupdate über CANopen-Schnittstelle möglich
* software update by using the CANopen interface
* Terminierung über Widerstand an Open Style 3polig
* termination with a resistor at the Open Style connector


= Description =
= Description =

Revision as of 11:31, 28 February 2007

----=== Translation is in progress! ===----

Manufacturer

Böhnke + Partner GmbH

Profil

CiA DSP-417

Interface

  • transceiver ISO 11898 conform (bus proof voltage +/- 30 V)
  • bitrate and -timing CiA DS-301 conform
  • galvanic insulated
  • auto baud detection
  • connector:
    • D-Sub 9-Pin
    • RJ45
    • Open Style with 3 contacts
  • NodeID 12 (parametrizable)
  • one state LED CiA DR-303-3 conform
  • software update by using the CANopen interface
  • termination with a resistor at the Open Style connector

Description

Die CLK-01 dient der Signalverarbeitung aller Kabinensignale eines Aufzuges. Sie stellt 16 Eingänge und 2 Relaisausgänge zur Verfügung. Sie ist mit der Platine CLE-01 um jeweils 32 Rufklemmen erweiterbar. Der CAN-Bus wird als Klemme, RJ45-Buchse und D-Sub 9polig zum Anschluss anderer Komponenten bereitgestellt.

State

Lieferbar

Picture