Manufacturer
Profil
CiA DSP-417
Interface
- transceiver ISO 11898 conform (bus proof voltage +/- 30 V)
- bitrate and -timing CiA DS-301 conform
- galvanic insulated
- auto baud detection
- connector:
- D-Sub 9-Pin
- RJ45
- Open Style with 3 contacts
- NodeID 12 (parametrizable)
- one state LED CiA DR-303-3 conform
- software update by using the CANopen interface
- termination with a resistor at the Open Style connector
Description
Die CLK-01 dient der Signalverarbeitung aller Kabinensignale eines Aufzuges. Sie stellt 16 Eingänge und 2 Relaisausgänge zur Verfügung. Sie ist mit der Platine CLE-01 um jeweils 32 Rufklemmen erweiterbar. Der CAN-Bus wird als Klemme, RJ45-Buchse und D-Sub 9polig zum Anschluss anderer Komponenten bereitgestellt.
State
Lieferbar