Here you can find a smal selection of projekts realised with CANopen CiA-417 components.
Simulator for the new airplane Airbus A380
realised by: FFG Fahrzeugwerkstätten Falkenried GmbH
1 ground touching passenger lift
Drive: 4 VVVF inverter, gearless, cogbelt drive
Q: 360 kg
V-Basic mast: 0,4 m/s
V-Telescope mast: 0,3 m/s
4 floors
CANopen-components
- Controller bp306
- Drive 4 Drive frequency converter Unidrive LFT (only CiA-403)
- Car electronic CAN-Leistungs-Platine CLK-01
- Positioning: the inverters read the 4 EnDat-Encoder and provide the absolut position for basic- and telescope mast
- Panels by bs tableau oHG
- Parameter setting with CANwizard
Deutsche Bahn Main Station, Berlin
realised by: Otis GmbH & Co. OHG
31 passenger lifts
Simplex, dublex and triplex groupes
CANopen-components
- Controllers bp306
- Car electronic CAN-Leistungs-Platine CLK-01
- Positioning Absolut position encoder GXP5W
Memorial St. Nikolai, Hamburg
realised by: HANS LUTZ MASCHINENFABRIK GMBH & CO.KG
Panorama lift
Drive: VVVF inverter, with gear
Q: 700 kg
v: 2,5 m/s
h: 77 m
3 floors
CANopen-components
- Controller bp306
- Car electronic CAN-Leistungs-Platine CLK-01
- Positioning Absolut position encoder GXP5W with slip correction
- Panels from bs tableau oHG
- Parameter setting with and remote diagnosis with the CANwizard and the CAN remote gateway CDG-01
Press releases
Hamburg church with a view - CANopen lifts visitors
Radisson SAS Hotel, Cologne
realised by: WINDSCHEID & WENDEL GmbH & Co.KG
7 passenger lifts
3 simplex lifts and a group of 4 lifts
v: 1,6 m/s
max. 9 floors
CANopen-components
- Controller bp306
- Car electronic CAN-Leistungs-Platine CLK-01
- Positioning Absolut position encoder GXP5W
- panels with CAN-Bus-Knoten cbk01
- Parameter setting with CANwizard
Lift at SCHAEFER GmbH
realised by: Brobeil Aufzüge GmbH & Co.KG
realised at: SCHAEFER GmbH
Personnel lift
4 Floors
- CANopen-Components:
- Controller bp306
- Car electronic CAN-Leistungs-Platine CLK-01
- Car Panel Unit with Panel Node CANnode CN16
- Hall Call Panel Unit with Hall Panel Node CANsmall CS08
- Remote Diagnosis with CAN remote gateway CDG-01
- Car Panel Unit with CAN-Adapter-Platine CAP-01
- Positioning Absolut position encoder GXP5W
- Positioning USP-30-CANopen
- Parameter setting with:
- Platform over CANwizard
- ActiveX-Control elements:
- Car Panel Node CANwizard_CN16
- Hall Panel Node CANwizard_CS08