Hall Panel Node CANsmall CS08: Difference between revisions
RSbySCHÄFER (talk | contribs) No edit summary |
RSbySCHÄFER (talk | contribs) No edit summary |
||
Line 7: | Line 7: | ||
=Profil= | =Profil= | ||
CiA-417 (hier fehlt noch der Link zum Molex Stecker) | CiA-417 (hier fehlt noch der Link zum Molex Stecker) | ||
=Description= | =Description= | ||
Line 23: | Line 21: | ||
Switching elements with recall light are connectable in 3- or 4-wire technology, common cathode. | Switching elements with recall light are connectable in 3- or 4-wire technology, common cathode. | ||
An input will be detected while the corresponding output ist set. This is possible at both wire techlologies. | |||
Following version are available: | Following version are available: | ||
Revision as of 11:17, 8 February 2008
Ruftableauknoten CANsmall CS08
Manufacturer
Profil
CiA-417 (hier fehlt noch der Link zum Molex Stecker)
Description
The CANsmall CS08 has 8 I/O terminals, 8 output terminals and contains the following virtual devices: Input Panel Unit and Output Panel Unit. The I/O terminals can be used for the calls, inputs- and outputs. So any input signal can be read in and sent to the CAN Bus as input-function. Also the output signals of the different lift controllers are read out via the I/O terminals or respectively output terminals.
The CANsmall CS08 is used for the connection of landing fixtures for lifts. It is available for face plate mounting or quick fastening.
Small dimensions approx. 55 x 35 mm. No DIP switches or jumper necessary. Node number and Baudrate are adjustable. Auto baud detection is possible.
Switching elements with recall light are connectable in 3- or 4-wire technology, common cathode. An input will be detected while the corresponding output ist set. This is possible at both wire techlologies.
Following version are available:
- CANsmall CS08_xST (4 slots up to 2 I/O-clamps per slot)
- CANsmall CS08_VST (Vertical clamps)
- CANsmall CS08_HST (Horizontal clamps)
- CANsmall CS08_xPM (1 slot f. SCHAEFER Diplay)
- CANsmall CS08_VPM (Vertical clamps)
- CANsmall CS08_HPM (Horizontal clamps)
Topology
Die Ruftableaus sind komplett vorverdrahtet von der Fa. SCHAEFER GmbH zu beziehen.
Eine Verdrahtung von Komponenten außerhalb des Ruftableaus ist nicht vorgesehen.
Die komplette Schacht-Verdrahtung beschränkt sich ausschließlich auf die
Busleitung und Stromversorgung.
Die Reihenfolge der Ruftableaus ist unter logischen Gesichtspunkten unerheblich.
Hierdurch sind potentielle Fehlerquellen bei der Schachtverdrahtung nahezu ausgeschlossen.
State
Following version are deliverable:
- CS08_VST
- CS08_VPM
- CS08_HST
- CS08_HPM