OMEGA 12-C: Difference between revisions

From CANopen-Lift
Jump to navigation Jump to search
No edit summary
Line 1: Line 1:
[[de:VK-OMEGA NG]]
[[de:OMEGA 12-C]]
= Manufacturer =
= Manufacturer =
[[Dinacell Electrónica, s.l]]
[[Dinacell Electrónica, s.l]]


= Profil =
= Profile =
CiA-417
CiA-417


Line 15: Line 15:


= Description =
= Description =
Unit control is a Load Weighing device of the (NG) New Generation units from Dinacell Electronic with CANopen-Lift CiA-417 integrated.
OMEGA 12-C unit control is a Load Weighing Device of the (NG) New Generation units from Dinacell Electronic with CANopen-Lift CiA-417 integrated.


The main features of this unit are:
The main features of this unit are:
* measuring, monitoring and limiting load in elevators.
* measuring, monitoring and limiting load in elevators.
* up to 12 individual rope tension monitoring
* 6 or 12 individual rope tension monitoring models.
* wire rope tension adjustment
* Wire rope tension adjustment, and slack rope tension detection
* 6 LED indicators
* 4 alarms LED indicators and 2 LED for Can Bus status.
* hold input
* Hold input to keep the weight unchanged when elevator is travelling.
* 4 alarm thresholds (Full Load, Over Load, Zero Cabin, Slack Rope Tension)
* 4 alarm thresholds (Full Load, Over Load, Zero Cabin, Slack Rope Tension)
* 4 relays output
* 4 relays outputs (Optional)
* 0-10 V analog output
* 0-10V or 0-5V analog output (Optional)
* 4-20 mA analog output
* 4-20 mA analog output (Optional)
* cabin display output
* Cabin display output (Optional)
* CANopen-Lift CiA-417
* CANopen-Lift CiA-417
* software chain compensation
* Software chain compensation
* hardware chain compensation
* Hardware chain compensation for largest buildings.


= State =
= Status =
in development
Available (May 2015)


or available


= Picture =
= Picture =

Revision as of 10:12, 18 May 2015

Manufacturer

Dinacell Electrónica, s.l

Profile

CiA-417

Interface

  • transceiver ISO 11898 conform (bus proof voltage +/- 30 V)
  • bitrate and -timing CiA-301 conform
  • galvanic insulated
  • connector: open style with 5 contacts
  • software update via USB
  • termination with a resistor at the open style connector

Description

OMEGA 12-C unit control is a Load Weighing Device of the (NG) New Generation units from Dinacell Electronic with CANopen-Lift CiA-417 integrated.

The main features of this unit are:

  • measuring, monitoring and limiting load in elevators.
  • 6 or 12 individual rope tension monitoring models.
  • Wire rope tension adjustment, and slack rope tension detection
  • 4 alarms LED indicators and 2 LED for Can Bus status.
  • Hold input to keep the weight unchanged when elevator is travelling.
  • 4 alarm thresholds (Full Load, Over Load, Zero Cabin, Slack Rope Tension)
  • 4 relays outputs (Optional)
  • 0-10V or 0-5V analog output (Optional)
  • 4-20 mA analog output (Optional)
  • Cabin display output (Optional)
  • CANopen-Lift CiA-417
  • Software chain compensation
  • Hardware chain compensation for largest buildings.

Status

Available (May 2015)